Our Products

 

SIGAS Rubber Mats offer optimum protection to maintenance areas as electrical cabinets. They are adaptable to various work conditions and complete the safety of workers.

High Voltage Insulation Sheet

High Voltage Insulation Sheet Image

Featureselectrical-insulation-sheet-04

  • Strong
  • abrasion resistant
  • easy to lay and slice
  • equipped with non-slip ribbing on the top
  • electrically insulating according to the standard IEC CEI 61111
  • Significantly consists with high level of flexibility
  • Excellent load bearing characteristic provides under heavy compression loads.
  • Resists to elevated temperatures up to 55°C.
  • Resistant to fluids of petroleum origin such as Brake fluid, polar oils etc

Finish: fine ribbed on the upper surface, fabric finished on the bottomelectrical-insulation-sheet-03

  • Unique characteristics of our electrical insulating mat:Unique characteristics of our electrical insulating mat:- Class 0 to Class 4, Maximum use voltage  36kV (A.C) 54Kv (D.C)- Suitable physical and mechanical properties to withstand trolley movement, mobile electrical equipment’s and foot traffic- Applicable for both AC & DC electrical insulation- Water and moisture resistance- Appropriate anti-skid properties- Excellent resistant against tearing and punching- Fire retardant, self-extinguishing properties- Exhibit good elongation & tensile strength properties- Manufactured without any metallic derivatives or carbon additives- Applicable for all fields of generation, transferring, distribution and consumption of electricity

 

electrical-insulation-sheet-01

When you seek for the right “Electrical Insulating Mat” manufacturer, try the ones which offer such a wide range of insulation mats under one roof.

Insulation mats are the essential parts of safety level protection for the workers who work across the industrial sectors.

From Low to High Voltage, our brand “SIGAS M@T” is manufactured as per the latest international standards and considerations.

The mats are manufactured using elastomeric materials. It is available from 2 to 6 mm thickness, depending on the working voltage up to 54 kV D.C.

Basically, there are six types of specialized international standards relevant to the electrical insulation mats:

–      Insulation Mats (IEC 61111:2009)

–      Electrical Insulating Mat (IS 15652:2006)

–      Insulating Matting (ASTM-D-178)

–      ISI Marked Insulating Mats (IS 15652:2006)

–      Rubber Mats (IS 5424:1969)

–      Insulation Matting (AS/NZS 2978:1995)

All the above-mentioned mattings are different from each other in terms of their features, technical specifications, as well as mechanical properties. But they are almost utilized for very common application areas that are related to electrically sensitive or hypersensitive establishments.

The application area of electrical insulation mats are summarized as follows:

–      Around Busbar,

–      Transformers,

–      Generators,

–      LV, MV, and HV rooms,

–      Near HT/LT Control Panels,

–      In front of Switchboards,

–     Electrical Substations,

–      And Outdoor/Indoor On-site use on Live Equipment.

It is always recommended to choose electrical insulating mats with the highest safety standards.

 

Test Results

  Test method
Specific gravity (grs/cm³)1.50DIN 53508
Hardness shore A ± 5°75DIN 53505
Tensile strength (Mpa)5DIN 53504
Elongation at break200DIN 53504

Technical Specifications

ClassThickness
(mm)
Proof Test VoltageResistanceMaximum Use VoltageWidth
(mtr)
Length
(mtr)
Colour
2420 kV30 kV17 kV1.0010Grey and Yellow
4640 kV50 kV36 kV1.0010Grey and Orange

Note: Specifications are subject to change without notice.

Category::
Industry
Sub-Category::
Electrical & ESD Mats

High Voltage Insulation Sheet

High Voltage Insulation Sheet Image

Featureselectrical-insulation-sheet-04

  • Strong
  • abrasion resistant
  • easy to lay and slice
  • equipped with non-slip ribbing on the top
  • electrically insulating according to the standard IEC CEI 61111
  • Significantly consists with high level of flexibility
  • Excellent load bearing characteristic provides under heavy compression loads.
  • Resists to elevated temperatures up to 55°C.
  • Resistant to fluids of petroleum origin such as Brake fluid, polar oils etc

Finish: fine ribbed on the upper surface, fabric finished on the bottomelectrical-insulation-sheet-03

  • Unique characteristics of our electrical insulating mat:Unique characteristics of our electrical insulating mat:- Class 0 to Class 4, Maximum use voltage  36kV (A.C) 54Kv (D.C)- Suitable physical and mechanical properties to withstand trolley movement, mobile electrical equipment’s and foot traffic- Applicable for both AC & DC electrical insulation- Water and moisture resistance- Appropriate anti-skid properties- Excellent resistant against tearing and punching- Fire retardant, self-extinguishing properties- Exhibit good elongation & tensile strength properties- Manufactured without any metallic derivatives or carbon additives- Applicable for all fields of generation, transferring, distribution and consumption of electricity

 

electrical-insulation-sheet-01

When you seek for the right “Electrical Insulating Mat” manufacturer, try the ones which offer such a wide range of insulation mats under one roof.

Insulation mats are the essential parts of safety level protection for the workers who work across the industrial sectors.

From Low to High Voltage, our brand “SIGAS M@T” is manufactured as per the latest international standards and considerations.

The mats are manufactured using elastomeric materials. It is available from 2 to 6 mm thickness, depending on the working voltage up to 54 kV D.C.

Basically, there are six types of specialized international standards relevant to the electrical insulation mats:

–      Insulation Mats (IEC 61111:2009)

–      Electrical Insulating Mat (IS 15652:2006)

–      Insulating Matting (ASTM-D-178)

–      ISI Marked Insulating Mats (IS 15652:2006)

–      Rubber Mats (IS 5424:1969)

–      Insulation Matting (AS/NZS 2978:1995)

All the above-mentioned mattings are different from each other in terms of their features, technical specifications, as well as mechanical properties. But they are almost utilized for very common application areas that are related to electrically sensitive or hypersensitive establishments.

The application area of electrical insulation mats are summarized as follows:

–      Around Busbar,

–      Transformers,

–      Generators,

–      LV, MV, and HV rooms,

–      Near HT/LT Control Panels,

–      In front of Switchboards,

–     Electrical Substations,

–      And Outdoor/Indoor On-site use on Live Equipment.

It is always recommended to choose electrical insulating mats with the highest safety standards.

 

Test Results

  Test method
Specific gravity (grs/cm³)1.50DIN 53508
Hardness shore A ± 5°75DIN 53505
Tensile strength (Mpa)5DIN 53504
Elongation at break200DIN 53504

Technical Specifications

ClassThickness
(mm)
Proof Test VoltageResistanceMaximum Use VoltageWidth
(mtr)
Length
(mtr)
Colour
2420 kV30 kV17 kV1.0010Grey and Yellow
4640 kV50 kV36 kV1.0010Grey and Orange

Note: Specifications are subject to change without notice.